Template:MOS modes/doc: Difference between revisions

From Xenharmonic Wiki
Jump to navigation Jump to search
Ganaram inukshuk (talk | contribs)
Collapse option
Ganaram inukshuk (talk | contribs)
Line 42: Line 42:
<pre>{{MOS modes|Scale Signature=4L 6s}}</pre>
<pre>{{MOS modes|Scale Signature=4L 6s}}</pre>
{{MOS modes|Scale Signature=4L 6s}}
{{MOS modes|Scale Signature=4L 6s}}
==== Collapsing the table ====
The table can be collapsed by default by passing a "1" for the Collapsed parameter. This is recommended for pages with too much information (such as MOS scales with a very large number of modes).
<pre>{{MOS modes|Scale Signature=4L 6s|Collapsed=1}}</pre>
{{MOS modes|Scale Signature=4L 6s|Collapsed=1}}


==== Adding mode names ====
==== Adding mode names ====

Revision as of 22:32, 24 July 2024

This template is used for mos pages to automatically generate and list that mos's modes, along with the modes' UDP.

Parameters

The template currently supports the following parameters:

Parameters Required? Description
Scale Signature Yes (optional on mos pages) The mos's scale signature in the form "xL ys", or for non-octave mosses, "xL ys<p/q>", "xL ys⟨p/q⟩", or "xL ys (p/q-equivalent)". If left blank and used on a mos page, then the page's title will be used.
Mode Names No (optional) A list of names delimited using semicolons. If provided, then a column for modes names are added. If the scale signature is "5L 2s", then mode names (Lydian, Ionian, etc) are automatically added.
Table Headers No (optional) A list of column headers delimited using semicolons, if more than one column of information is needed. If either this or the parameter Entries are left blank, no columns are added.
Table Entries No (optional) A list of entries delimited using semicolons, if more than one column of information is needed. There must be as many entries as there are as headers multiplied by modes, or no columns will be added. If either this or the Headers parameter are left blank, no columns are added.
Collapsed No (optional) An option to have the table collapsed. Enter "1" to have the table collapsed by default.

Usage

For mos pages, which is the typical use, simply include the code below.

{{MOS modes}}

Using a different scale signature

To specify a scale signature different from the title of the page, include it as shown below. Non-octave mosses are supported, as are multi-period mosses.

{{MOS modes|Scale Signature=5L 3s}}
Modes of 5L 3s
UDP Cyclic
order
Step
pattern
7|0 1 LLsLLsLs
6|1 4 LLsLsLLs
5|2 7 LsLLsLLs
4|3 2 LsLLsLsL
3|4 5 LsLsLLsL
2|5 8 sLLsLLsL
1|6 3 sLLsLsLL
0|7 6 sLsLLsLL
{{MOS modes|Scale Signature=4L 5s <3/1>}}
Modes of 4L 5s⟨3/1⟩
UDP Cyclic
order
Step
pattern
8|0 1 LsLsLsLss
7|1 3 LsLsLssLs
6|2 5 LsLssLsLs
5|3 7 LssLsLsLs
4|4 9 sLsLsLsLs
3|5 2 sLsLsLssL
2|6 4 sLsLssLsL
1|7 6 sLssLsLsL
0|8 8 ssLsLsLsL
{{MOS modes|Scale Signature=4L 6s}}
Modes of 4L 6s
UDP Cyclic
order
Step
pattern
8|0(2) 1 LsLssLsLss
6|2(2) 3 LssLsLssLs
4|4(2) 5 sLsLssLsLs
2|6(2) 2 sLssLsLssL
0|8(2) 4 ssLsLssLsL

Collapsing the table

The table can be collapsed by default by passing a "1" for the Collapsed parameter. This is recommended for pages with too much information (such as MOS scales with a very large number of modes).

{{MOS modes|Scale Signature=4L 6s|Collapsed=1}}
Modes of 4L 6s
UDP Cyclic
order
Step
pattern
8|0(2) 1 LsLssLsLss
6|2(2) 3 LssLsLssLs
4|4(2) 5 sLsLssLsLs
2|6(2) 2 sLssLsLssL
0|8(2) 4 ssLsLssLsL

Adding mode names

Names for each mode are separated by semicolons, as shown below. A mode may have multiple names (such as with 5L 3s) or a name consisting of multiple words (such as with the mode names described by Elaine Walker for 4L 5s <3/1>). The number of mode names must match the number of modes the mos has, or the column won't be added.

{{MOS modes|Scale Signature=5L 3s|Mode Names=Dylathian, Dylian; Ilarnekian; Celephaïsian; Ultharian; Mnarian; Kadathian, Kadian; Hlanithian, Hlanian; Sarnathian, Sarnian}}
Modes of 5L 3s
UDP Cyclic
order
Step
pattern
7|0 1 LLsLLsLs
6|1 4 LLsLsLLs
5|2 7 LsLLsLLs
4|3 2 LsLLsLsL
3|4 5 LsLsLLsL
2|5 8 sLLsLLsL
1|6 3 sLLsLsLL
0|7 6 sLsLLsLL
{{MOS modes|Scale Signature=4L 5s <3/1>|Mode Names=Walker I; Walker II; Moll I (Delta); Lambda; Moll II (Pierce); Harmonic; Dur I; Walker A; Walker B}}
Modes of 4L 5s⟨3/1⟩
UDP Cyclic
order
Step
pattern
8|0 1 LsLsLsLss
7|1 3 LsLsLssLs
6|2 5 LsLssLsLs
5|3 7 LssLsLsLs
4|4 9 sLsLsLsLs
3|5 2 sLsLsLssL
2|6 4 sLsLssLsL
1|7 6 sLssLsLsL
0|8 8 ssLsLsLsL

Adding multiple columns

In situations where more than one column is needed, list the headers and entries as shown below. Entries are filled in by row. The two examples show mode names added in two ways – using Mode Names and Entries – so both examples produce the same table.

{{MOS modes|Scale Signature=6L 3s|Table Headers=Mode name; Name origin|Table Entries=Zeldan; Named after Zelda; Linkan; Named after Link; Ganan, Ganondoran; Named after Ganon/Ganondorf}}
{{MOS modes|Scale Signature=6L 3s|Mode Names=Zeldan; Linkan; Ganan, Ganondoran|Table Headers=Name origin|Table Entries=Named after Zelda; Named after Link; Named after Ganon/Ganondorf}}
Modes of 6L 3s
UDP Cyclic
order
Step
pattern
6|0(3) 1 LLsLLsLLs
3|3(3) 2 LsLLsLLsL
0|6(3) 3 sLLsLLsLL

Limitations

If adding table entries through the Entries parameter, blank entries cannot be entered and the table rows and headers won't be added.

See also